bioscan 817 network settings

The bioscan 817 connects to biotime in one of three ways: Ethernet, WiFi, or 4G using a full-sized SIM card. Over Ethernet or WiFi, the clock can either pick up its details automatically from your network (DHCP) or be given a static IP address.

This guide shows you how to set up each one. Some steps, such as setting a static IP address, involve network settings, so it's best suited to the person who manages your network, or to someone working alongside them.

Opening Android System Settings

Ethernet, WiFi and time zone settings are all changed in Android System Settings, which you open from the Admin menu. The steps are shown once here and linked from each section, so you can jump between them.

  1. Press Admin in the top right corner of the display.

  2. Enter your Administrator ID and press Enter, then verify as prompted (finger, card or PIN). The main menu is displayed.

  3. Select System Maintenance from the left menu column.

The bioscan 817 admin main menu, with step 3 marking System Maintenance in the left column

3 Select System Maintenance
  1. On the System Maintenance screen, select Android System Settings.

The System Maintenance screen, with step 4 marking Android System Settings

4 Select Android System Settings

Ethernet

Important

Before the clock is installed, the data point it plugs into needs to be patched and connected to an active port on the network switch. This is usually done by a cabling contractor and it's worth confirming the completed step is tested as live before installation day.

A clock plugged into a data point that isn't live will show as offline, no matter how it's set up. The Ethernet port on the bioscan 817 has no status lights, so there's no link light to check. If the clock is still offline, a quick way to rule this out is to plug a laptop with its WiFi turned off into the same data point and check that it gets a network connection.

Using DHCP (default)

The simplest way to connect the bioscan 817 is wired Ethernet using DHCP. In this mode the clock automatically gets the network details it needs (IP address, subnet mask, gateway and DNS) from the local network.

Once the cable is plugged in, see Confirming the clock is connected to check the clock has an IP address.

If it hasn't, restarting the clock is the next step, see Restart the clock.

Using a static IP address

To manually set an IP address for the wired Ethernet connection, first open Android System Settings by following Opening Android System Settings. Then:

  1. On the Android Settings screen, select Ethernet which is enabled by default, but check the toggle at the top right is on.

The Android Ethernet settings screen, with step 1 marking the Ethernet toggle switched on

1 Check the toggle is switched on
  1. Scroll down and select Ethernet IP mode.

  2. Select Static.

The Ethernet IP mode dialog over the Ethernet settings screen, with step 2 marking the Ethernet IP mode row and step 3 the static option

2 Select Ethernet IP mode3 Select static
  1. Use the keypad to enter the IP Address.

  2. Hide the keypad with the triangle key on the black bar (or swipe up), then complete Netmask, Gateway, DNS1 and DNS2.

The Ethernet static IP dialog with the on-screen keypad, with step 4 marking the IP address field and step 5 marking the triangle key that hides the keypad

4 Enter the IP address5 Hide the keypad
  1. When all relevant fields have been completed, press Connect.

  2. Press the Circle key at the bottom of the screen to return to bioscan, then press Save to exit the Admin menu.

The Ethernet static IP dialog with the fields completed and the Android navigation bar below, with step 6 marking the fields and step 7 marking the Circle key

6 Complete the fields, then press Connect7 Press the Circle key

Once saved, see Confirming the clock is connected to check the clock is using the address you entered.

If it isn't, restarting the clock is the next step, see Restart the clock.

Technical note for your IT contact

If the clock uses a static IP, make sure that address is excluded from the DHCP range. Two devices with the same address will cause the connection to drop. If you would rather reserve the address in your DHCP server, the clock's MAC address can be used to do so.

WiFi

If an Ethernet cable is also plugged in, the clock uses Ethernet in preference to WiFi, even when the WiFi is connected. The steps below also connect the clock to a mobile hotspot (unplug the Ethernet cable first). This is a quick way to tell whether the problem is with the company's network or not.

The bioscan 817 supports 2.4 GHz WiFi only. If your access point broadcasts separate 2.4 GHz and 5 GHz networks you won't see the 5 GHz network.

Before you start, check both antennas (WiFi and mobile) are attached to the mounts on the top of the clock.

The top of the bioscan 817 with both antennas attached to their mounts, beside the power button

Connecting to a WiFi network

To enable and configure the WiFi interface, first open Android System Settings by following Opening Android System Settings. Then:

  1. On the Android Settings screen, select Wi-Fi. The WiFi screen is displayed.

  2. WiFi is enabled by default, but check the toggle at the top right is on. After a few seconds, a list of available WiFi networks is displayed. The signal icon beside each network shows how strong it is: the fuller the icon, the stronger the signal.

The WiFi settings screen with WiFi on, with step 2 marking the WiFi toggle

2 Check WiFi is on
  1. Select your WiFi network, enter its password and press Connect.

The WiFi password dialog, with step 3 marking the Connect button

3 Press Connect

If valid credentials were entered, the WiFi network will show status Connected.

Using a static IP address over WiFi

To set a static IP address instead of using DHCP, first connect to the network by following Connecting to a WiFi network. Then change its settings:

  1. Press and hold the network, then select Modify network.

The press-and-hold menu for a WiFi network, with step 1 marking Modify network

1 Select Modify network
  1. Press Advanced options.

The WiFi password dialog, with step 2 marking Advanced options

2 Open Advanced options
  1. Press the arrow next to IP settings and select Static.

The WiFi password dialog with the IP settings list open, with step 3 marking Static

3 Select Static
  1. Use the keypad to enter the IP address.

  2. Hide the keypad with the triangle key on the black bar (or swipe up), then complete Gateway, Network prefix length (for example, 24), DNS 1 and DNS 2.

The WiFi static IP fields, with step 4 marking the IP address
4 Enter the IP address
The WiFi static IP fields scrolled down to the Network prefix length, DNS 1 and DNS 2
5 Complete the remaining fields
  1. Press Save. If valid credentials were entered, the WiFi network will show status Connected.
Technical note for your IT contact

If the clock uses a static IP, make sure that address is excluded from the DHCP range. Two devices with the same address will cause the connection to drop. If you would rather reserve the address in your DHCP server, the clock's MAC address can be used to do so.

If the network shows Authentication problem

If the wrong password was entered, the network will show status Authentication problem instead of Connected. This is a common cause of a clock that won't join WiFi. To fix it, re-enter the password:

The WiFi settings screen with a network showing the status Authentication problem

  1. Press and hold the network, then select Modify network.

The press-and-hold menu for a WiFi network, with step 1 marking Modify network

1 Select Modify network
  1. Enter the correct password and press Save.

The Modify network dialog, with step 2 marking the Password field

2 Enter the correct password

Alternatively, choose Forget network from the same menu, then select the network again and enter its password from the start.

Once the clock shows Connected, see Confirming the clock is connected to check it has an IP address.

If it hasn't, restarting the clock is the next step, see Restart the clock.

4G

The bioscan 817 can connect over 4G instead of Ethernet or WiFi. You need a full-sized SIM card with an active mobile data plan from a provider that has coverage where the clock is installed. Any provider will do.

biotime doesn't supply or manage SIM cards or mobile plans, so you'll need to arrange this with your provider. Make sure the plan always has data available. If the plan runs out, the clock will go offline.

  1. Insert the SIM card into the SIM slot on the bottom of the clock with the gold contact points facing upwards and the cut out on the top right. It can only go in one way, so gently push it in until it clicks. Once inserted, it looks like this:

The ports on the bottom of the bioscan 817 with a SIM card pushed into its slot, marked 1, beside the USB, HDMI and Ethernet ports

1 Gently push the SIM card in until it clicks
  1. Check both antennas (WiFi and mobile) are attached to the mounts on the top of the clock, as shown here:

The top of the bioscan 817 with both antennas attached to their mounts, beside the power button

  1. Restart the clock if it was already on when you inserted the SIM card, because the clock only looks for a SIM card when it starts up. See Restart the clock.
Important

The clock always prefers Ethernet when a cable is connected. If the internet drops but the cable is still connected to the router or switch, the clock won't switch to 4G. It only uses 4G when the Ethernet link is gone completely, so unplug the Ethernet cable if you want the clock to use 4G.

Once the clock has restarted, see Confirming the clock is connected to check it has an IP address. Over 4G, the address shown is a public IP address, so it looks different from the usual 192.168 address:

The bioscan 817 diagnostics screen showing a public IP address beside IP Address, marked 1

1 Over 4G, the IP address is a public address

Confirming the clock is connected

Whichever connection method you have set up, confirm that the clock has picked up an IP address. If you are still in the Android settings, press the Circle key at the bottom of the screen, then press Save to exit the Admin menu.

  1. Tap the bioscan logo in the top left corner of the screen to open the diagnostics screen.

The top navigation bar of the bioscan 817 home screen, with the bioscan logo in the top left corner outlined and marked 1

1 Tap the bioscan logo to open the diagnostics screen
  1. Check the IP Address line. A valid address (for example, 192.168.1.25) means the clock is connected to your network. If you set a static IP address, it should match the address you entered. On a 4G SIM, the address shown is the mobile connection's WAN IP, in the same format. If the brackets are empty, the clock hasn't been given an address, so check the cable or WiFi connection. The two cases look like this:

Two diagnostics screens compared. Top: a valid IP address beside IP Address, marked 1. Bottom: empty brackets beside IP Address, marked 2

1 A valid IP address2 Empty brackets mean the clock has no IP address

If the clock still shows OFFLINE, see Troubleshooting an offline bioscan 817 for what the rest of the diagnostics screen shows.

Date, time and time zone

If the clock's date and time are wrong, there are two likely causes: the wrong time zone is selected, or the time has drifted because it isn't syncing with a time server.

Setting the time zone

Not every state observes daylight saving, so a clock set to the wrong city can be an hour out for part of the year. For example, Queensland doesn't observe it, so a Queensland clock needs the Brisbane time zone rather than Sydney's. This issue often occurs when a clock is sent to a site in another state and the time zone isn't changed. To change the time zone, first open Android System Settings by following Opening Android System Settings. Then:

  1. In the Android settings, scroll down to the System section and select Date & time.

  2. Make sure Automatic time zone is turned off.

  3. Tap Select time zone.

The Android Date & time screen showing the time zone as GMT+11:00, with 2 marking Automatic time zone turned off and 3 marking Select time zone

2 Turn Automatic time zone off3 Select time zone
  1. Choose the time zone and daylight saving rules for the city that matches your site.

The Select time zone list, with 4 marking Brisbane at GMT+10:00

4 Select the city that matches your site
  1. The Date & time screen now shows the correct time zone.

The Android Date & time screen showing the time zone set to GMT+10:00 Australian Eastern Standard Time

  1. Press the Circle key at the bottom of the screen to leave the Android settings, then press Save to exit the Admin menu.

  2. Check the date and time on the clock's home screen.

The clock home screen, with 7 marking the time and date

7 Check the date and time

Checking the time sync (NTP)

The clock keeps its time in sync with a time server (NTP). If the time drifts significantly, the clock can struggle to connect securely to the server, so it's worth checking if a clock is offline for no obvious reason.

Open the Admin menu by following steps 1 and 2 of Opening Android System Settings. Then:

  1. Select bioscan from the left menu column.

  2. Select Time Synchronization.

The bioscan tab on the Admin menu, with 1 marking bioscan and 2 marking Time Synchronization

1 Select bioscan2 Select Time Synchronization
  1. The screen shows the NTP server (pool.ntp.org by default), the port (123) and the sync interval (30 min). Select Force NTP Sync to sync now.

  2. Select Show NTP Log to check for a response received entry. If you need to change the settings, use Edit Server, Edit Port or Edit Interval.

The NTP screen, with 3 marking Force NTP Sync and 4 marking Show NTP Log

3 Force NTP Sync4 Show NTP Log

The NTP log, showing the latest NTP response received entry

Technical note for your IT contact

The clock syncs its time with pool.ntp.org on port 123. If your network blocks that server or port, the time will drift. Ask your IT contact to allow it, or to point the clock at an NTP server the network permits.

The date and time on the diagnostics screen might be shown in universal time (UTC), so they can look 8, 10 or 12 hours out from local time. That's expected.

If the clock still shows OFFLINE

If the clock still shows this message once the connection is set up, see Troubleshooting an offline bioscan 817.

The bioscan 817 home screen showing the message that the device is operating in OFFLINE mode

Related

Need a hand?

Our support team knows biotime inside out. Send us a message and we’ll get back to you, usually within one business day.

Get in touch

Prefer to call? AU 1300 139 460 · NZ 0800 111 438
From overseas: +61 7 5613 2700 · +64 9 820 3444
Monday to Friday, 8:30am – 5:00pm (AEST/NZST)